5KW All-in-one solar charger inverter

9,000.0013,000.00 (-31%)

In stock

Main Features

◎ Pure sine wave inverter
◎ Output power factor 0.8
◎ Built-in battery equalization function to extend battery life cycle
◎ Built-in MPPT solar charge controller
◎ Selectable input voltage range for home appliances and personal computers
◎ Selectable charging current based on applications
◎ Configurable AC/Solar input priority via LCD setting
◎ Compatible to mains voltage or generator power
◎ Battery equalization for optimized battery performance and lifecycle
◎ Parallel operation with up to 9 units only available

Compare
SKU: 5kw-Hybrid-Inverter Categories: ,

All-in-one solar charger inverter

 

SR-HFP4850S80-145

Product overview

HFP series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard.

Performance characteristics

  • Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sinewave.
  • Two output modes: mains bypass and inverter output; uninterrupted power supply.
  • Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging.
  • Advanced MPPT technology with an efficiency of 99.9%.·With the charging requirement (voltage, current, mode) settings, and suitable for various types of energystorage batteries.
  • ON/OFF rocker switch for AC output control.
  • Power saving mode available to reduce no-load loss.·Intelligent variable speed fan to efficiently dissipate heat and extend system life.
  • Lithium battery activation design, allowing access of lead-acid battery and lithium battery.
  • 360 ° all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent.
  • Supply of a variety of user-friendly communication modules, such as RS485(GPRS, WiFi, Bluetooth), CAN, USB etc., and suitable for computer, mobile phones, Internet monitoring as well as remote operations.
  • Available for 6 units parallel connection.

    Product connection diagram example                            Appearance

Overload protector 10 RS485-1 communication port
ON/OFF rocker switch 11 Dry contact port
AC input port 12 Cooling fan
AC output port 13 Battery port
Grounding screw hold 14 Cooling fan
RS485-2 communication port 15 PV port
     Current sharing port  (parallel module only) 16 Touch the key lightly
Parallel communication port (parallel module only) 17 Indicator light
USB communication port 18 LCD screen
Models HFP4850S80-145
AC mode
Rated input voltage 220/230Vac
Input voltage range (170Vac~280Vac) ±2%;(90Vac-280Vac)±2%

Frequency                                                                                                                                       50Hz/ 60Hz (Auto detection)

Number of parallel / split phases Frequency Range

Overload/short circuit protection

Efficiency

Conversion time (bypass and inverter)

AC reverse protection

1-6

47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);

Circuit breaker

>95%

10ms (typical)

Available

Maximum bypass overload current                                                                                                                    40A

Inverter mode
Output voltage waveform Pure sine wave
Rated output power (VA) 5000
Rated output power (W) 5000
Power factor 1
Rated output voltage (Vac) 230Vac
Output voltage error ±5%
Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
Maximum Efficiency >92%
Overload protection (102% < load <125%) ±10%: report error and turn off the output after 5 minutes;

(125% < load < 150%) ±10%: report error and turnoff the output after 10 seconds;

Load >150% ±10%: report error and turn off the output after 5 seconds;

Peak power 10 000VA
Loaded motor capability 3HP
Output short circuit protection Circuit breaker
Bypass breaker specifications 40A
Rated battery input voltage 48V (Minimum starting voltage 44V)

Battery voltage range                                                      Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery… settable on LCD screen)

Power saving mode Load ≤50W
AC charging
Battery type Lead acid or lithium battery ad acid or lithium battery
Maximum charge current 60A
Charge current error ± 35Adc c
Charge voltage range 40 –58Vdc
Short circuit protection Circuit breaker and blown fuse Circuit breaker and blown fuse
Circuit breaker specifications 40A
Overcharge protection                           Alarm and turn off charging after 1 minute Alarm a                      rn off charging after 1 minute
PV charging

Maximum PV open circuit voltage                                                                                                                  145Vdc

PV operating voltage range 60-145Vdc
MPPT voltage range 60-11560-115VdcVdc
Battery voltage range 40-60Vdc
Maximum PV input power 4400W
Maximum PV input current 50A
Maximum charger power 4200W

PV charging current range (can be set)                                                                                                            0-80A

Charging short circuit protection Blown fuseBlown fuse

Wiring protection                                                                                                                            Reverse polarity protection

Certified specifications
Certification CE( IEC  62109-1)
EMC certification level EN61000, C2

Operating temperature range                                                                                                                     -15°C to 55°C

Storage temperature range -25°C ~ 60°C
Humidity range 5% to 95% (Conformal coating protection)
Noise ≤60dB
Heat dissipation Forced air cooling, variable speed of fan
Communication interface USB/RS485(WiFi/GPRS)/Dry node control
Size (L*W*D) 426mm*322mm*124mm
Weight (kg) 10.8

All-in-one solar charger inverter

 

SR-HFP4850S80-145

Product overview

HFP series is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard.

Performance characteristics

  • Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sinewave.
  • Two output modes: mains bypass and inverter output; uninterrupted power supply.
  • Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging.
  • Advanced MPPT technology with an efficiency of 99.9%.·With the charging requirement (voltage, current, mode) settings, and suitable for various types of energystorage batteries.
  • ON/OFF rocker switch for AC output control.
  • Power saving mode available to reduce no-load loss.·Intelligent variable speed fan to efficiently dissipate heat and extend system life.
  • Lithium battery activation design, allowing access of lead-acid battery and lithium battery.
  • 360 ° all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent.
  • Supply of a variety of user-friendly communication modules, such as RS485(GPRS, WiFi, Bluetooth), CAN, USB etc., and suitable for computer, mobile phones, Internet monitoring as well as remote operations.
  • Available for 6 units parallel connection.

    Product connection diagram example                            Appearance

Overload protector 10 RS485-1 communication port
ON/OFF rocker switch 11 Dry contact port
AC input port 12 Cooling fan
AC output port 13 Battery port
Grounding screw hold 14 Cooling fan
RS485-2 communication port 15 PV port
     Current sharing port  (parallel module only) 16 Touch the key lightly
Parallel communication port (parallel module only) 17 Indicator light
USB communication port 18 LCD screen
Models HFP4850S80-145
AC mode
Rated input voltage 220/230Vac
Input voltage range (170Vac~280Vac) ±2%;(90Vac-280Vac)±2%

Frequency                                                                                                                                       50Hz/ 60Hz (Auto detection)

Number of parallel / split phases Frequency Range

Overload/short circuit protection

Efficiency

Conversion time (bypass and inverter)

AC reverse protection

1-6

47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);

Circuit breaker

>95%

10ms (typical)

Available

Maximum bypass overload current                                                                                                                    40A

Inverter mode
Output voltage waveform Pure sine wave
Rated output power (VA) 5000
Rated output power (W) 5000
Power factor 1
Rated output voltage (Vac) 230Vac
Output voltage error ±5%
Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
Maximum Efficiency >92%
Overload protection (102% < load <125%) ±10%: report error and turn off the output after 5 minutes;

(125% < load < 150%) ±10%: report error and turnoff the output after 10 seconds;

Load >150% ±10%: report error and turn off the output after 5 seconds;

Peak power 10 000VA
Loaded motor capability 3HP
Output short circuit protection Circuit breaker
Bypass breaker specifications 40A
Rated battery input voltage 48V (Minimum starting voltage 44V)

Battery voltage range                                                      Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery… settable on LCD screen)

Power saving mode Load ≤50W
AC charging
Battery type Lead acid or lithium battery ad acid or lithium battery
Maximum charge current 60A
Charge current error ± 35Adc c
Charge voltage range 40 –58Vdc
Short circuit protection Circuit breaker and blown fuse Circuit breaker and blown fuse
Circuit breaker specifications 40A
Overcharge protection                           Alarm and turn off charging after 1 minute Alarm a                      rn off charging after 1 minute
PV charging

Maximum PV open circuit voltage                                                                                                                  145Vdc

PV operating voltage range 60-145Vdc
MPPT voltage range 60-11560-115VdcVdc
Battery voltage range 40-60Vdc
Maximum PV input power 4400W
Maximum PV input current 50A
Maximum charger power 4200W

PV charging current range (can be set)                                                                                                            0-80A

Charging short circuit protection Blown fuseBlown fuse

Wiring protection                                                                                                                            Reverse polarity protection

Certified specifications
Certification CE( IEC  62109-1)
EMC certification level EN61000, C2

Operating temperature range                                                                                                                     -15°C to 55°C

Storage temperature range -25°C ~ 60°C
Humidity range 5% to 95% (Conformal coating protection)
Noise ≤60dB
Heat dissipation Forced air cooling, variable speed of fan
Communication interface USB/RS485(WiFi/GPRS)/Dry node control
Size (L*W*D) 426mm*322mm*124mm
Weight (kg) 10.8

 

Submit your review

Your email address will not be published.

Reviews

There are no reviews yet.

See It Styled On Instagram

    Instagram did not return a 200.

Main Menu