GENERAL DATA

HEIGHT 497 mm
WIDTH 460 mm
DEPTH 176 mm
WEIGHT 20.5 kg
DEGREE OF PROTECTION IP 65
PROTECTION CLASS 1
OVERVOLTAGE CATEGORY
(DC / AC)
NA
NIGHT-TIME CONSUMPTION 5.0 w
INVERTER DESIGN Transformerless
COOLING Convection
INSTALLATION Indoors and outdoors
AMBIENT TEMPERATURE RANGE ‒25 °C to +60 °C (‒13 °F to +140 °F)
PERMITTED HUMIDITY 0 – 100 %
MAX. ALTITUDE 3000 m
DC CONNECTION TECHNOLOGY SUNCLIX DC connector
AC CONNECTION TECHNOLOGY AC connector
CERTIFICATES AND COMPLIANCE WITH STANDARDS AS 4777.2, C10/11, CE, CEI 0-21, EN 50438, G59/3-4, G83/2-1,
DIN EN 62109 / IEC 62109, NEN-EN50438, ÖVE/ÖNORM E 8001-4-712 &
TOR D4, PPC, PPDS, RD1699, SI4777, TR3.2.1, UTE C15-712, VDE-AR-N 4105,
VDE0126-1-1, VFR 2014, RfG compliant
DEWA, IEC 61727, IEC 62116, IE-EN50438, MEA, NBR16149,
NT_Ley20.571, PEA, TR3.2.2

EFFICIENCY

MAXIMUM EFFICIENCY (PV – GRID) 98.3 %
EUROPEAN EFFICIENCY (ΗEU) 98.0 %

PROTECTION DEVICES

DC REVERSE POLARITY PROTECTION Short-circuit diode
INPUT-SIDE DISCONNECTION POINT DC Load-Break Switch
AC SHORT-CIRCUIT CURRENT CAPABILITY Current control
GRID MONITORING SMA Grid Guard 10.0
Maximum overcurrent protection 32 A
Ground fault monitoring Insulation monitoring: Riso > 200 kΩ
All-pole sensitive residual-current monitoring unit Available
Compare

INPUT DATA

NUMBER OF MPP TRACKERS 2
MAX. INPUT CURRENT (IDC MAX / IMPPT MAX) 27.0 / 16.5 A
MAX. SHORT CIRCUIT CURRENT, MODULE ARRAY 40.5 / 24.8 A
DC INPUT VOLTAGE RANGE (UDC MIN – UDC MAX) 200 – 1000 V
FEED-IN START VOLTAGE (UDC START) 200 V
NOMINAL INPUT VOLTAGE (UDC,R) 600 V
MPP VOLTAGE RANGE (UMPP MIN – UMPP MAX) 270 – 800 V
USABLE MPP VOLTAGE RANGE 200 – 800 V
NUMBER OF DC CONNECTIONS 3 + 3
MAX. PV GENERATOR POWER (PDC MAX) 15 kWpeak

OUTPUT DATA

AC NOMINAL OUTPUT (PAC,R) 10 kW
MAX. OUTPUT POWER (PAC MAX) 10 kVA
AC OUTPUT CURRENT (IAC NOM) 14.4 A
GRID CONNECTION (UAC,R) 3~ NPE 400/230, 3~ NPE 380/220 V
AC VOLTAGE RANGE (UMIN – UMAX) 150 – 280 V
FREQUENCY (FR) 50 / 60 Hz
FREQUENCY RANGE (FMIN – FMAX) 45 – 65 Hz
TOTAL HARMONIC DISTORTION 1.8 %
POWER FACTOR (COS ΦAC,R) 0 – 1 ind./cap.

GENERAL DATA

HEIGHT 725 mm
WIDTH 510 mm
DEPTH 225 mm
WEIGHT 34.8 kg
DEGREE OF PROTECTION IP 66
PROTECTION CLASS 1
OVERVOLTAGE CATEGORY
(DC / AC)
2 / 3
NIGHT-TIME CONSUMPTION < 1 w
INVERTER DESIGN Transformerless
COOLING Regulated air cooling
INSTALLATION Indoors and outdoors
AMBIENT TEMPERATURE RANGE -40°C – +60°C
PERMITTED HUMIDITY 0 – 100 %
MAX. ALTITUDE 2,000 m / 3,400 m
DC CONNECTION TECHNOLOGY 6x DC+ and 6x DC- screw terminals 2.5 – 16 mm²
AC CONNECTION TECHNOLOGY 5-pin AC screw terminals 2.5 – 16 mm²
CERTIFICATES AND COMPLIANCE WITH STANDARDS ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100,
AS 4777-2, AS 4777-3, CER 06-190, G83/2, UNE 206007-1, SI 4777, CEI 0-16, CEI 0-21, NRS 097

EFFICIENCY

MAXIMUM EFFICIENCY (PV – GRID) 98 %
EUROPEAN EFFICIENCY (ΗEU) 97.4 %
Η AT 5% PAC,R 87.9 / 92.5 / 89.2 %
Η AT 10% PAC,R 91.2 / 94.9 / 92.8 %
Η AT 20% PAC,R 94.6 / 97.1 / 96.1 %
Η AT 25% PAC,R 95.4 / 97.3 / 96.6 %
Η AT 30% PAC,R 95.6 / 97.5 / 96.9 %
Η AT 50% PAC,R 96.3 / 97.9 / 97.4 %
Η AT 75% PAC,R 96.5 / 98.0 / 97.6 %
Η AT 100% PAC,R 96.5 / 98.0 / 97.6 %
MPP ADAPTATION EFFICIENCY > 99.9 %

PROTECTION DEVICES

DC INSULATION MEASUREMENT Yes
OVERLOAD BEHAVIOUR Operating point shift, power limitation
DC DISCONNECTOR Yes
REVERSE POLARITY PROTECTION Yes

INTERFACES

WLAN / ETHERNET LAN Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 INPUTS AND 4 DIGITAL INPUTS/OUTPUTS Interface to ripple control receiver
USB (TYPE A SOCKET) Data logging, inverter update via USB flash drive
2X RS422 (RJ45 SOCKET) Fronius Solar Net
SIGNALLING OUTPUT Energy management (floating relay output)
DATALOGGER AND WEB SERVER Integrated
EXTERNAL INPUT S0 meter connection / Evaluation of overvoltage protection
RS485 Modbus RTU SunSpec or meter connection

INPUT DATA

NUMBER OF MPP TRACKERS 2
MAX. INPUT CURRENT (IDC MAX / IMPPT MAX) 20 A / 12 A
MAX. SHORT CIRCUIT CURRENT, MODULE ARRAY 30 A / 18 A
DC INPUT VOLTAGE RANGE (UDC MIN – UDC MAX) 125 – 1000 V
FEED-IN START VOLTAGE (UDC START) 150 V
NOMINAL INPUT VOLTAGE (UDC,R) 580 V
MPP VOLTAGE RANGE (UMPP MIN – UMPP MAX) 320 – 800 V
USABLE MPP VOLTAGE RANGE 320 – 800 V
NUMBER OF DC CONNECTIONS A:2; B:1
MAX. PV GENERATOR POWER (PDC MAX) 15 kWpeak

OUTPUT DATA

AC NOMINAL OUTPUT (PAC,R) 10 kW
MAX. OUTPUT POWER (PAC MAX) 10 kVA
AC OUTPUT CURRENT (IAC NOM) 14.4 A
GRID CONNECTION (UAC,R) 3 / N / PE; 220 V / 380 V
3 / N / PE; 230 V / 400 V
3 / N / PE; 240 V / 415 V
AC VOLTAGE RANGE (UMIN – UMAX) 180 – 280 V
FREQUENCY (FR) 50 Hz / 45 Hz to 55 Hz
60 Hz / 55 Hz to 65 Hz
FREQUENCY RANGE (FMIN – FMAX) 50 Hz / 45 Hz to 55 Hz
60 Hz / 55 Hz to 65 Hz
TOTAL HARMONIC DISTORTION < 3 %
POWER FACTOR (COS ΦAC,R) 1 / 0.8 overexcited to 0.8 underexcited
Submit your review

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    Instagram did not return a 200.

Main Menu